Forrige Neste
Slutter
Underlagt tilbud
 
  
Du vil bekrefte dette tilbudet på neste side. Hvordan Gi tilbud fungerer. Hvordan Gi tilbud fungerer.
13 som kikker på
PRODUKTDETALJER
Kjørelengde
0 Miles
MVA
Counter Flow Drum, 3 ft x 8 ft Control House, 3 Bin Cold Feeder, 12 in x 4 ft 6 in Collecting Conveyor, 18 in x 11 ft 4 in Transfer Conveyor, 4 ft 2 in Diameter 14 ft 9 in Length Counter Flow Drum, Baghouse with Fine Return System, AC Tank, FBR Hot Oil Heater, 18 ftx11.5 in Drag Slat Conveyor, Twin Shaft Mixer, 3 ft x 8 ft Control House, Air Conditioning, Computerized Controls, T/A Mounted, Spring Suspension,


***THIS ITEM IS ELIGIBLE TO IMPORT INTO THE USA / HAS EPA**

FUNCTIONALITY COULD NOT BE VERIFIED / LA FUNCIONALIDAD NO PUDO SER VERIFICADA

No es suceptible a plaqueo estatal o federal

Inspeksjonsrapport



Vennligst merk at du som kjøper er ansvarlig for å se gjennom hele inspeksjonsrapporten når du vurderer en vare.


Generelt utseende
Beskrivelse Vurdering Detaljer  
(17)


Cold Feed System
Beskrivelse Vurdering Detaljer  
(23)


Dryer/Mixer Drum
Beskrivelse Vurdering Detaljer  
(26)


Dust Collector
Beskrivelse Vurdering Detaljer  
(11)


AC System
Beskrivelse Vurdering Detaljer  
(15)


Hot Elevator
Beskrivelse Vurdering Detaljer  
(13)


Batch Mixer
Beskrivelse Vurdering Detaljer  
(6)


Control House
Beskrivelse Vurdering Detaljer  
(13)
 
Tvister:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.