Måleravlesning
4 083 Timer
Serie #
Enclosed Cab, 19200 mm Max Lift Height, Cummins 6 Cylinder Diesel Engine

Inspeksjonsrapport



Vær oppmerksom på at du byr på et produkt som tilbys uten IronClad Assurance®. Bare grunnleggende detaljer om varetilstand gis for din vurdering i en kjøpsbeslutning.
 
Model Description
Beskrivelse Detaljer
 
Functionality
Beskrivelse Detaljer
Electric The electrical system is operational.
Engine The engine started and ran.
Drivetrain The drivetrain engages in forward and reverse.
Hydraulics The hydraulic system could not be operationally checked.
Deficiencies Deficient Components/Systems Include but are not limited to: Boom Disconnected, Missing Travel Alarm, Hydraulic Fluid Around Hyd Tank, Engine Oil Gauge Not Operational, Most Work Lights Not Operational

Denne varen tilbys< span klasse = "varsel"> som er, hvor-er uten IronClad forsikring, og en kjøper kan ikke bestride tilstanden til varen. IronPlanet påtar seg intet ansvar for tilstanden eller beskrivelsen av dette elementet. Varen inkluderer ikke beskyttelse som tilbys av IronClad Assurance. En kjøper kan IKKE sende et tvistekrav knyttet till varen.


Generelt utseende
Beskrivelse Vurdering Detaljer  
CE-merke CE Marked
Hour Meter / Odometer 4083 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Klikk her for å åpne bilder og videoer av denne varen.  
(39)


Control Station Photos
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Beskrivelse Vurdering Detaljer  
(19)


Engine
Beskrivelse Vurdering Detaljer  
(3)


Drivetrain Photos
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Beskrivelse Vurdering Detaljer  
(12)


Hydraulics Photos
See photos for condition
Beskrivelse Vurdering Detaljer  
(15)


Chassis Photos
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Beskrivelse Vurdering Detaljer  
(37)
 